Time and pulse counters (single counter) for AC or DC or with Twintechnology as time, service or pulse counters (double counter) 7 mm digit height, 48 x 24 mm

Advanced BAUSER technology enables: Even without battery, your information remains registered in the EEPROM records. Further, the digital time- and pulse counters offer a smart design, high quality and reliability. Therefore, ideally suitable for the heavy applications in the industry and vehicles.

With the BAUSER counters, you can count on:

  • LC-display with 7 digits, character height 7 mm
  • Plug- and terminal connection

The BAUSER-Twin (double counter) registers cost effectively two different counting values as digital indication in just one counter. So, we offer you two counters in one unit. You decide which value should be indicated permanently and which one in the background. We programme the BAUSER-Twin individually for you, according to your priorities and requirements of service intervals and prewarning times.

Digital time and pulse counters 3800

Housing:

Black plastic

Indication:

LC-display with 7 digits (only active while connected)

Character height:

7 mm

Operating voltages:

12 – 24 V DC / ±25 %
110 – 240 V AC 50/60 Hz / ±10 %

Special voltages (at additional cost):

24 – 48 V DC / ±25 %
24 V AC/DC / ±10 %

Current consumption:

12 – 24 V DC and 24 – 48 V DC / <5 mA
24 V AC / DC / <10 mA
110 – 240 V AC 50/60 Hz / <15 mA

Ambient temperature:

–30°C to +70 °C

Stocking temperature:

–40°C to +80 °C

Electrical Connection:

Plug connection 6,3 x 0,8 mm / 90° bent or terminal connection

Reset:

Without, manual or electrical

Protection:

Without reset button IP 65, with reset button IP 54

Vibration resistance:

20 g according to SAEJ1378, 1 g (10...500 Hz) according to EN 60068-2-34

Shock resistance:

55 g according to SAEJ1378, 30 g (18 ms) according to EN 60068-2-27,
25 g (6 ms) according to EN 60068-2-29

EMC:

EN 55011, EN 61000-6-2

Industrial norm:

EN 61010, protection class II

Approval:

CE, optional UL/cUL

Counting frequency / pulse counter:

30 or 200 Hz = DC-counter
10 HZ = AC-Counter

Data storage:

EEPROM (min. 25 years)

Fixing:

Retaining clip

Weight:

39 g