CAN | CANopen | SAE J1939 Emmission Control Tier 4

Excellent visualisation: 3.5” display, 320x240 pixels, 4 buttons, 4 LED warning lamps, digital and analogue inputs as well as a CAN-bus interface with CANopen or SAE J1939 protocols, RTC with battery backup for date and time, further clear text indications like errors, diagnostic data etc.

Please send us your requirements and we would find a fitting solution for you.

CAN | CANopen | SAE J1939 Emmission Control Tier 4

Casing:

Material: PBT-GB30, black Front side: chemical and UV resistant polyester foil Viewing area: low-reflective mineral glass

Display:

3,5“ TFT colour LCD, transmissive

Resolution:

QVGA, 320x240 pixels, 16-bit colour

Aspect ratio:

4:3

Mounting direction:

Horizontal

Warning lamps:

4 LEDs, can be read clearly under direct sunlight

Buttons:

4 buttons with a clear tactile feedback

Electrical interfaces:

2x analogue or digital inputs (custom configuration)
1x digital input
1x voltage supply measuring
1x CAN ISO 11898 interface

Protocol:

CANopen, SAE J1939

Date and time:

Real Time Clock with internal battery backup

Voltage supply:

8…36 VDC

Ambient temperature:

-30°C…+85°C

Storage temperature:

-40°C…+85°C

Electrical connection:

Compatible with 10 pole VW connector type 6X0 973 815

Fixing:

Metal clamps with screws

Protection class:

IP67 front, IP40 back (optionally IP65)

Vibration resistance:

EN 60068-2-64

Shock resistance:

EN 60068-2-27, EN 60068-2-29

EMC:

DIN EN 12895, EN 55022, EN 61000-4-2, -3, -4, -6, ISO 7637-2, -3, ISO 16750-2

Approval:

CE

Options:

GoretexTM membrane, back IP65, backlit buttons, second CAN ISO 11898 interface, buzzer, fixing with 4 snap-in-clamps (shorter mounting depth), custom front foil, mounting direction: vertical, 5 LED warning lamps, electrical connection: Tyco Super Seal, 26 poles, instruments with TFT colour displays in 4.3”, 5” and 7” – on request